Roboteq Dual Channel Digital Motor Controller AX500 Bedienungsanleitung Seite 116

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 154
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 115
Serial (RS-232) Controls and Operation
116 AX500 Motor Controller Users Manual Version 1.9b. June 1, 2007
Acceleration
Address: ^03
Access: Read/Write
Effective: After Reset or ^FF
This parameter configures the rate at which the controller internally changes the command
value from the one it was to the one just received.
Input Switches Function
Address: ^04
Access: Read/Write
Effective: After Reset or ^FF
This parameter enables and configures the effect of the controllers Digital Inputs and other
settings.
Bit Definition See pages
7:0 0 = very slow
1 = slow
(2) = medium-slow (default)
3 = medium
4 = fast
5 = fastest
See Programmable Acceleration
on page 40 for complete list of
acceptable values
Bit Definition See pages
1:0 Enable and
Configure
Invert/Estop
(00) = Input Disabled (default)
01 = Input as Emergency Stop
10 = Disabled
11 = Input as Invert Command
page 45
page 45
2 Output C when
Motor On
(0) = No Action (default)
1 = Output C On when either motor is On
page 45
3 Encoder Safety Unavailable
Seitenansicht 115
1 2 ... 111 112 113 114 115 116 117 118 119 120 121 ... 153 154

Kommentare zu diesen Handbüchern

Keine Kommentare